데이터셋 상세
미국
OCO-3 Level 1B calibrated, geolocated science spectra, Forward Processing V10 (OCO3 L1B Science) at GES DISC
Version 10 is the current version of the data set. Older versions will no longer be available and are superseded by Version 10. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
연관 데이터
OCO-3 Level 1B calibrated, geolocated science spectra, Retrospective Processing V10r (OCO3 L1B Science) at GES DISC
공공데이터포털
Version 10r is the current version of the data set. Older versions will no longer be available and are superseded by Version 10r. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 1B calibrated, geolocated science spectra, Forward Processing V11 (OCO3 L1B Science) at GES DISC
공공데이터포털
Version 11 is the current version of the data set. Older versions will no longer be available and are superseded by Version 11. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 1B calibrated, geolocated calibration spectra, V10 (OCO3 L1B Calibration) at GES DISC
공공데이터포털
Version 10 is the current version of the data set. Older versions will no longer be available and are superseded by Version 10. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. The OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Their raw data numbers (DN) are delivered correlated in time to the Level 1B process as Level 1A products. Each band has 1016 spectralelements, although some are masked out in the L2 retrieval. This L1B product results from calibration mode measurements (e.g., Lunar,Solar, Dark observations), and thus it differs from the OCO3_L1B_Science (L1bSc) product. The differences in the product formats are only in the geolocation information provided. Whereas the L1bSc products report geolocation data for each sounding, calibration products report the direction of the boresight vector.
OCO-3 Level 1B calibrated, geolocated calibration spectra, Retrospective Processing V10r (OCO3 L1B Calibration) at GES DISC
공공데이터포털
Version 10r is the current version of the data set. Older versions will no longer be available and are superseded by Version 10r. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. The OCO-3 incorporates three high-resolution spectrometers that make coincident measurements ofreflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Their raw data numbers (DN) are delivered correlated in time to the Level 1B process as Level 1A products. Each band has 1016 spectralelements, although some are masked out in the L2 retrieval. This L1B product results from calibration mode measurements (e.g., Lunar,Solar, Dark observations), and thus it differs from the OCO3_L1B_Science(L1bSc) product. The differences in the product formats are only in the geolocation information provided. Whereas the L1bSc products report geolocation data for each sounding, calibration products report the directionof the boresight vector.This is the retrospective processing where the calibration data is estimated from the full timeseries of data (before, during, and after the measurements), and is expected to be of slightly higher quality. This is the retrospective processing where the calibration data is estimated from the full timeseries of data (before, during, and after the measurements), and is expected to be of slightly higher quality.
OCO-3 Level 1B calibrated, geolocated science spectra, Retrospective Processing V11r (OCO3 L1B Science) at GES DISC
공공데이터포털
Version 11r is the current version of the data set. Older versions will no longer be available and are superseded by Version 11r. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 1B calibrated, geolocated calibration spectra, Retrospective Processing V11r (OCO3 L1B Calibration) at GES DISC
공공데이터포털
Version 11r is the current version of the data set. Older versions will no longer be available and are superseded by Version 11r. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. The OCO-3 incorporates three high-resolution spectrometers that make coincident measurements ofreflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Their raw data numbers (DN) are delivered correlated in time to the Level 1B process as Level 1A products. Each band has 1016 spectralelements, although some are masked out in the L2 retrieval. This L1B product results from calibration mode measurements (e.g., Lunar,Solar, Dark observations), and thus it differs from the OCO3_L1B_Science(L1bSc) product. The differences in the product formats are only in the geolocation information provided. Whereas the L1bSc products report geolocation data for each sounding, calibration products report the directionof the boresight vector.This is the retrospective processing where the calibration data is estimated from the full timeseries of data (before, during, and after the measurements), and is expected to be of slightly higher quality. This is the retrospective processing where the calibration data is estimated from the full timeseries of data (before, during, and after the measurements), and is expected to be of slightly higher quality.
OCO-3 Level 2 spatially ordered geolocated retrievals screened using the A-band Preprocessor, Forward Processing V10 (OCO3 L2 ABand) at GES DISC
공공데이터포털
Version 10 is the current version of the data set. Older versions will no longer be available and are superseded by Version 10. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 2 geolocated XCO2 retrieval results and algorithm diagnostic information, Forward Processing V10 (OCO3 L2 Diagnostic) at GES DISC
공공데이터포털
Version 10 is the current version of the data set. Older versions will no longer be available and are superseded by Version 10. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 1B calibrated, geolocated science spectra, Retrospective Processing V10r (OCO3 L1B Science) at GES DISC
공공데이터포털
Version 10r is the current version of the data set. Older versions will no longer be available and are superseded by Version 10r.The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2.The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere.OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations.The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.
OCO-3 Level 2 spatially ordered geolocated retrievals screened using the A-band Preprocessor, Retrospective Processing V10r (OCO3 L2 ABand) at GES DISC
공공데이터포털
Version 10r is the current version of the data set. Older versions will no longer be available and are superseded by Version 10r. The Orbiting Carbon Observatory -3 (OCO-3) was deployed to the International Space Station in May, 2019. It is technically a single instrument, almost identical to OCO-2. The Orbiting Carbon Observatory is the first NASA mission designed to collect space-based measurements of atmospheric carbon dioxide with the precision, resolution, and coverage needed to characterize the processes controlling its buildup in the atmosphere. OCO-3 incorporates three high-resolution spectrometers that make coincident measurements of reflected sunlight in the near-infrared CO2 near 1.61 and 2.06 micrometers and in molecular oxygen (O2) A-Band at 0.76 micrometers. The three spectrometers have different characteristics and are calibrated independently. Oxygen-A Band cloud screening algorithm is one of the primary cloud screening tools implemented in the operational OCO processing pipeline. The algorithm was introduced and applied to early GOSAT data with further analysis performed on OCO-2 simulations. The OCO ABO2 algorithm employs a fast Bayesian retrieval to estimate surface pressure and surface albedo from high resolution spectra of the molecular oxygen (O2) A-band, near 0.765 µm. The radiative transfer forward model (FM) assumes a clear-sky condition, i.e. Rayleigh scattering only, such that differences between the modeled and measured radiances are apparent when the measurement scene contains cloud or aerosol.