데이터셋 상세
미국
Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1 in Brine 1 with Different Starting pHs at 70C
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous submission we reported data for shaker bath tests for brine #1 with starting pH's of 3.5, 4.5 and 5.5. In this submission we these pH's compared to starting brine #1 pH's of 6, and 7.
연관 데이터
Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1 in Brine 1 with Different Starting pHs at 70C
공공데이터포털
This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous submission we reported data for shaker bath tests for brine #1 with starting pH's of 3.5, 4.5 and 5.5. In this submission we these pH's compared to starting brine #1 pH's of 6, and 7.
REE Sorption Study of Seived -50 +100 Mesh Fraction of Media 1 in Brine 1 at Different Concentrations of REE at 70C
공공데이터포털
This dataset shows the sorption capacities of smaller grain size (-50 +100 mesh) of media #1 in brine #1 at different starting concentrations of REE's at elevated temperature of 70C. The experimental conditions are 2g of -50 +100 mesh media #1 to 150mL of REE solution at concentrations of .2ppm each, 2ppm each, and 20ppm each. The pH of the solution is 5.5, and the temperature was at 70C.
REE Sorption Study of Seived -50 +100 Mesh Fraction of Media 1 in Brine 1 at Different Concentrations of REE at 70C
공공데이터포털
This dataset shows the sorption capacities of smaller grain size (-50 +100 mesh) of media #1 in brine #1 at different starting concentrations of REE's at elevated temperature of 70C. The experimental conditions are 2g of -50 +100 mesh media #1 to 150mL of REE solution at concentrations of .2ppm each, 2ppm each, and 20ppm each. The pH of the solution is 5.5, and the temperature was at 70C.
Shaker Table Experiments with Rare Earth Elements Sorption from Geothermal Brine
공공데이터포털
This dataset described shaker table experiments ran with sieved -50 +100 mesh media #1 in brine #1 that have 2ppm each of the 7 REE metals at different starting pH's of 3.5, 4.5, and 5.5. The experimental conditions are 2g media to 150mL of REE solution, at 70C.
Shaker Test Results Comparing Rare Earth Element Sorption Between Natural and Doped Simulated Geothermal Brine
공공데이터포털
Shaker test data comparing rare earth element (REE) sorption onto Tusaar media between one natural geothermal brine and two simulated brines doped with known mineral concentrations.
Experimental Parameters Affecting Stripping of Rare Earth Elements from Loaded Sorptive Media in Simulated Geothermal Brines
공공데이터포털
Experimental results from several studies exploring the impact of pH and acid volume on the stripping of rare earth elements (REEs) loaded onto ligand-based media via an active column. The REEs in this experiment were loaded onto the media through exposure to a simulated geothermal brine with known mineral concentrations. The data include the experiment results, rare earth element concentrations, and the experimental parameters varied.
Comparison of Rare Earth Element Sorption Between Fresh and Partially Loaded Media Using Simulated Geothermal Brine
공공데이터포털
A study comparing the REE sorption characteristics of fresh ligand-based sorption media and media partially loaded with REEs when exposed to a simulated geothermal brine with known mineral concentrations, REE7. Sorption rates were tested using microcosm shaker tests. Results suggest that preferential REE sorption is greater for fresh media, but this preference differs between elements.
Comparison of Rare Earth Element Sorption Between Fresh and Partially Loaded Media Using Simulated Geothermal Brine
공공데이터포털
A study comparing the REE sorption characteristics of fresh ligand-based sorption media and media partially loaded with REEs when exposed to a simulated geothermal brine with known mineral concentrations, REE7. Sorption rates were tested using microcosm shaker tests. Results suggest that preferential REE sorption is greater for fresh media, but this preference differs between elements.
Improved Rare Earth Element Sorption from Simulated Geothermal Brines: Effect of Gassed versus Degassed Brines
공공데이터포털
A study exploring sorption and stripping characteristics of sorption media when simulated geothermal brines are degassed or not degassed. Experiments were done at 70degC. The brines used in this study were formulated by Tusaar. The two brines used/simulated are labeled 1M and 1CF. The data consists of a Word file explaining the results and an Excel file of the data.
Improved Rare Earth Element Sorption from Simulated Geothermal Brines: Effect of Gassed versus Degassed Brines
공공데이터포털
A study exploring sorption and stripping characteristics of sorption media when simulated geothermal brines are degassed or not degassed. Experiments were done at 70degC. The brines used in this study were formulated by Tusaar. The two brines used/simulated are labeled 1M and 1CF. The data consists of a Word file explaining the results and an Excel file of the data.