Surface Meteorological Station - PNNL 10m Sonic, Physics site-5 - Raw Data
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
데이터 정보
연관 데이터
Surface Meteorological Station - PNNL 10m Sonic, Physics site-4 - Raw Data
공공데이터포털
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-10 - Raw Data
공공데이터포털
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-5 - Reviewed Data
공공데이터포털
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-4 - Reviewed Data
공공데이터포털
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-10 - Reviewed Data
공공데이터포털
**Overview** This dataset provides fast response wind and virtual sonic temperature data. **Data Details** Each meteorological (met) station has one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) has been verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. The sonic anemometer has been oriented to magnetic North. The serial data stream is transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The current version of the data is ".a0." level. All evidently erroneous and/or broken lines were marked as bad and/or replaced with a "baddata" place holder, the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The data have been prepared for processing with EddyPro and stored in ASCII comma delimited files formatted as follows: u,v,w,T,qc where: * "u, v, w" are the three wind components (m/s) * "T" is the sonic virtual temperature (C) * "qc" is basic quality control code: 0 - OK, 1 - sonic bad data code, 2 - broken data line, and 3 - missed line. Baddata place holder is 99.99 **NOTE**: No attempt has been made to fill gaps in the data. **Data Quality** * Includes raw data with basic quality control (QC) applied. * All housekeeping fields removed.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-5 - Derived Data
공공데이터포털
**Overview** This set provides estimation of the turbulent fluxes obtained with EddyPro v6.2.0 software (15-min averaging). **Data Details** Each meteorological station had one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) was verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. NOTE: the sonic anemometer has been oriented to the magnetic North. The serial data stream was transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The raw data were preprocessed to conform with EddyPro software. All evidently erroneous and/or broken lines were marked as bad. All erroneous or missed data were replaced with "baddata" place holder (99.99), the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The preprocessed data are available from the archive as “.a0” level data. The current dataset is the result of processing the preprocessed data (“.a0”) with EddyPro v6.2.0 for 15-minute intervals. The dataset contains results and metadata that should fully cover all software settings and options used in data processing. **Data Quality** Beyond the Quality Control (QC) procedures implemented in EddyPro, nothing additional is included.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-4 - Derived Data
공공데이터포털
**Overview** This set provides estimation of the turbulent fluxes obtained with EddyPro v6.2.0 software (15-min averaging). **Data Details** Each meteorological station had one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) was verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. NOTE: the sonic anemometer has been oriented to the magnetic North. The serial data stream was transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The raw data were preprocessed to conform with EddyPro software. All evidently erroneous and/or broken lines were marked as bad. All erroneous or missed data were replaced with "baddata" place holder (99.99), the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The preprocessed data are available from the archive as “.a0” level data. The current dataset is the result of processing the preprocessed data (“.a0”) with EddyPro v6.2.0 for 15-minute intervals. The dataset contains results and metadata that should fully cover all software settings and options used in data processing. **Data Quality** Beyond the Quality Control (QC) procedures implemented in EddyPro, nothing additional is included.
Surface Meteorological Station - PNNL 10m Sonic, Physics site-10 - Derived Data
공공데이터포털
**Overview** This set provides estimation of the turbulent fluxes obtained with EddyPro v6.2.0 software (15-min averaging). **Data Details** Each meteorological station had one sonic anemometer (Gill R3-50, omnidirectional) mounted on top of a 10-m tower. Sensor verticality (within a degree) was verified by the analog inclinometer mounted on the base plate alongside the sonic anemometer. NOTE: the sonic anemometer has been oriented to the magnetic North. The serial data stream was transmitted via radio link (9XTend RF modem by MaxStream) to the data acquisition computer housed in a temperature-controlled enclosure at the base of the 80-m tower. The original data were stored in flat ASCII files in 30-min pieces (".00." level). The raw data were preprocessed to conform with EddyPro software. All evidently erroneous and/or broken lines were marked as bad. All erroneous or missed data were replaced with "baddata" place holder (99.99), the housekeeping data were stripped off, and the data were split into 5-min portions with no internal time stamp. The preprocessed data are available from the archive as “.a0” level data. The current dataset is the result of processing the preprocessed data (“.a0”) with EddyPro v6.2.0 for 15-minute intervals. The dataset contains results and metadata that should fully cover all software settings and options used in data processing. **Data Quality** Beyond the Quality Control (QC) procedures implemented in EddyPro, nothing additional is included.
Surface Meteorological Station - ANL 10m, (1) Sonic, Physics site-9 - Raw Data
공공데이터포털
**Overview** Sonic anemometers from Physics Site-3 and Site-9 provide wind components and virtual temperature. The energy balance Bowen ratio (EBBR) station at Physics site-3 provides measurements of the surface fluxes of latent and sensible heat, net radiation, and surface soil heat flux. **Data Quality** Data will be automatically screened using similar maximum/minimum range limits used, for example, for the Atmospheric Radiation Measurement EBBR systems. Data also will be visually inspected for outliers and obviously incorrect data periods.
Surface Meteorological Station - UND 10m, (2) Sonics 3m 10m, (2) T/RH 3m 10m, Physics site-11 - Raw Data
공공데이터포털
**Overview** The data included features wind, temperature, and turbulence measurements. **Data Details** Each met station (met.z18, met.z19, met.z21, and met.z23) consists of multiple levels of three-dimensional ultrasonic anemometers, RM Young 81000 (sampling frequency = 20 Hz), and temperature/relative humidity probes, Rotronics HC2S3 (sampling frequency = 1 Hz). The HC2S3 probes were housed in radiation shields to protect them from thermal radiation, and they were adequately ventilated. Moreover, an infrared gas analyzer (LI-7500 Open Path CO~2/H~2~O Analyzer) was collocated at 3-meter height at met.z18 (sampling frequency = 20 Hz) in a second phase of the experiment (June 2016). Raw data are collected by Campbell CR3000 dataloggers and successively parsed into 15-minutes data files. For each met station, multiple data files are outputted with each data file corresponding to a certain type of instrument and a specific measurement height. The types of instrument and measurement heights are specified by the name of the data file itself. For example, met station met.z19 consists of sonic anemometers measurements at 3-, 10-, and 17-meter height and temperature/relative humidity measurements at 3- and 17-meter height. Therefore, the following data files are outputted: 3m sonic anemometer sample file name: met.z19.00.20160502.171500.son03m.dat 10m sonic anemometer sample file name: met.z19.00.20160502.171500.son10m.dat 17m sonic anemometer sample file name: met.z19.00.20160502.171500.son17m.dat 3m T-RH sensor sample file name: met.z19.00.20160502.171500.trh03m.dat 17m T-RH sensor sample file name: met.z19.00.20160502.171500.trh17m.dat Note that in the "Primary Measurements/Variables" section, the variables sonic_u-wind, sonic_v-wind, sonic_w-wind represent the orthogonal u, v, and w wind velocities outputted by the sonic RM Young 81000, oriented with u-axis aligned east-west and v-axis aligned north-south. In this orientation, +u values = wind from the east, and +v values = wind from the north. Wind from below (updraft) = +w. Instruments' manuals and dataset samples are provided as attachments. **Data Quality** Raw data: no quality control (QC) is applied. Data are visually inspected at least weekly. **Uncertainty** 1. RM Young 81000 Ultrasonic Anemometer Measurements * Anything that blocks the acoustic signal path will degrade the measurement. * If the path is blocked sufficiently, measurements cannot be made. The RM Young 81000 can make accurate measurements in driving rain, but light mist or heavy fog can allow droplets to accumulate on the transducer faces and block the measurement. * Measurements may be made in driving snow, although frost and snow that adheres to the transducer face may block the measurement. Similarly, freezing rain on the transducer face may block the measurement. 2. Rotronics HC2S3 Temperature and Relative Humidity Measurement * This sensor requires minimal maintenance, but dust, debris, and salts on the filter cap may degrade sensor performance. Because of the remote location and difficulties in climbing the met towers, no maintenance of these sensors was performed during the field experiment. 3. Licor LI-7500 Measurement * The LI-7500 optical windows should be cleaned when necessary (by checking the diagnostic values). * Rain, snow, fog, condensation, or dust deposition on the optical path of the instrument may affect the gas analyzer's performance and lead to less consistent/missing measurements. Because of the remote location and difficulties in climbing the met towers, no maintenance of these sensors was performed during the field experiment.