StingRAY Structural Optimization Final Technical Report
공공데이터포털
The overall project objective is to materially decrease the leveled cost of energy (LCOE) of the Columbia Power (CPower) StingRAY utility-scale wave energy converter (WEC). This will be achieved by reducing structural material and manufacturing costs and increasing energy output. In this Project, improving the overall Power-to-Weight ratio (PWR) is accomplished through lowering design margins?allowing for weight reduction and more efficient, cost-effective WEC manufacturing and assembly?and by optimizing mass-related WEC performance parameters, such as center of gravity and system inertia. A mixed materials approach to further structural optimization was developed under this Project and validated with extensive laboratory structural testing. This approach substitutes fiber-reinforced plastic (FRP) for steel where appropriate. The benefits of steel are maintained where most useful, for instance at structural joints where the stiffness of steel is required, and the complex geometry is more readily fabricated with steel. However, there are structural spans whose simple shapes are readily fabricated with mandrel-wound FRP and where significant cost and weight savings can be found. An adhesive, double lap shear joint is used to join the FRP and steel subcomponents.
StingRAY Structural Optimization Final Technical Report
공공데이터포털
The overall project objective is to materially decrease the leveled cost of energy (LCOE) of the Columbia Power (CPower) StingRAY utility-scale wave energy converter (WEC). This will be achieved by reducing structural material and manufacturing costs and increasing energy output. In this Project, improving the overall Power-to-Weight ratio (PWR) is accomplished through lowering design margins?allowing for weight reduction and more efficient, cost-effective WEC manufacturing and assembly?and by optimizing mass-related WEC performance parameters, such as center of gravity and system inertia. A mixed materials approach to further structural optimization was developed under this Project and validated with extensive laboratory structural testing. This approach substitutes fiber-reinforced plastic (FRP) for steel where appropriate. The benefits of steel are maintained where most useful, for instance at structural joints where the stiffness of steel is required, and the complex geometry is more readily fabricated with steel. However, there are structural spans whose simple shapes are readily fabricated with mandrel-wound FRP and where significant cost and weight savings can be found. An adhesive, double lap shear joint is used to join the FRP and steel subcomponents.
StingRAY Structural Optimization Final Technical Report Appendices
공공데이터포털
The protected data appendices to the public Final Technical Report. The overall project objective is to materially decrease the leveled cost of energy (LCOE) of the Columbia Power (CPower) StingRAY utility-scale wave energy converter (WEC). This will be achieved by reducing structural material and manufacturing costs and increasing energy output. In this Project, improving the overall Power-to-Weight ratio (PWR) is accomplished through lowering design margins?allowing for weight reduction and more efficient, cost-effective WEC manufacturing and assembly?and by optimizing mass-related WEC performance parameters, such as center of gravity and system inertia. A mixed materials approach to further structural optimization was developed under this Project and validated with extensive laboratory structural testing. This approach substitutes fiber-reinforced plastic (FRP) for steel where appropriate. The benefits of steel are maintained where most useful, for instance at structural joints where the stiffness of steel is required, and the complex geometry is more readily fabricated with steel. However, there are structural spans whose simple shapes are readily fabricated with mandrel-wound FRP and where significant cost and weight savings can be found. An adhesive, double lap shear joint is used to join the FRP and steel subcomponents
Techno-Economic Analysis of AquaHarmonics Wave Energy Converter Using SAM: Baseline and Optimized LCOE Estimates
공공데이터포털
This dataset presents techno-economic modeling results for the AquaHarmonics Wave Energy Converter (WEC), analyzing both baseline and optimized system configurations using the National Renewable Energy Laboratory's System Advisor Model (SAM). The models incorporate empirical performance data and simulate deployment at the PacWave South test site off the coast of Newport, Oregon. Included are SAM-generated reports and a project file detailing device and array specifications, energy production estimates, capital and operational costs, and resulting Levelized Cost of Energy (LCOE) calculations. The data provides comparative insights into design improvements and their impact on system performance and cost. SAM software is required to view and interact with the project file, and can be downloaded via the attached link.
Centipod WEC, Advanced Controls, Resultant LCOE
공공데이터포털
Project resultant levelized cost of energy (LCOE) model after implementation of model predictive control (MPC) controller. Contains annual energy production (AEP) data, cost breakdown structure (CBS), model documentation, and the LCOE content model. This is meant for comparison with this project's baseline LCOE model.