데이터셋 상세
미국
RivGen Deployment Control System Specifications and Models, Igiugig, AK
Control System simulation models, case studies, and processing codes for analyzing field data. Raw data files included from VFD and SCADA. MatLab and Simulink are required to open some data files and all model files.
데이터 정보
연관 데이터
RivGen Deployment Control System Specifications and Models, Igiugig, AK
공공데이터포털
Control System simulation models, case studies, and processing codes for analyzing field data. Raw data files included from VFD and SCADA. MatLab and Simulink are required to open some data files and all model files.
RivGen Power System Overview, Igiugig, AK
공공데이터포털
System description of ORPC RivGen(R) Power System utilized at Igiugig, AK for testing of advanced controls
RivGen Power System Overview, Igiugig, AK
공공데이터포털
System description of ORPC RivGen(R) Power System utilized at Igiugig, AK for testing of advanced controls
Simulink Model of a New Energy EVG-005 5kW Hydropower Turbine
공공데이터포털
Simulink model for a New Energy 5kW hydropower turbine. ADCP data ("ds_streamwise_7_13.nc") and DC voltage, DC current, and rotor rotation observed from the New Energy EVG-005 Current Energy Converter (CEC) ("electrical_7_13_10ohms.nc") were collected at the Tanana River Test Site (TRTS) near Nenana Alaska. - Data was collected on July 13th, 2023 with a constant 10 ohms resistance applied with a DC load bank. - Simulink model is meant to resemble the electrical setup at the TRTS. - Model is initialized by running the "NewEnergy_2023_10hz.m" Matlab script. Then the Simulink model ("New_Energy_Model_PMSM.slx") can be run. - Results are processed with the "NewEnergy_2023_processing.m" Matlab code. The Matlab results are also saved in the "New_Energy_7_13_model_validation_results.mat" Matlab file. This can be directly loaded into the Matlab Workspace using the "Load()" command. - The timetable variables "electrical_model_downsampled" is the model results and the "electrical_limited" is the experimental data from the TRTS.
Simulink Model of a New Energy EVG-005 5kW Hydropower Turbine
공공데이터포털
Simulink model for a New Energy 5kW hydropower turbine. ADCP data ("ds_streamwise_7_13.nc") and DC voltage, DC current, and rotor rotation observed from the New Energy EVG-005 Current Energy Converter (CEC) ("electrical_7_13_10ohms.nc") were collected at the Tanana River Test Site (TRTS) near Nenana Alaska. - Data was collected on July 13th, 2023 with a constant 10 ohms resistance applied with a DC load bank. - Simulink model is meant to resemble the electrical setup at the TRTS. - Model is initialized by running the "NewEnergy_2023_10hz.m" Matlab script. Then the Simulink model ("New_Energy_Model_PMSM.slx") can be run. - Results are processed with the "NewEnergy_2023_processing.m" Matlab code. The Matlab results are also saved in the "New_Energy_7_13_model_validation_results.mat" Matlab file. This can be directly loaded into the Matlab Workspace using the "Load()" command. - The timetable variables "electrical_model_downsampled" is the model results and the "electrical_limited" is the experimental data from the TRTS.
Advanced TidGen Power System - Control and SCADA System
공공데이터포털
The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. This submission includes a technical report on control system development, supporting simulations and supervisory control and data acquisition (SCADA) system requirements. Also included is the final design of the control and SCADA system, with supporting simulations and risk mitigation control strategies to address major system technical risks.
Advanced TidGen Power System - Control and SCADA System
공공데이터포털
The TidGen Power System generates emission-free electricity from tidal currents and connects directly into existing grids using smart grid technology. The power system consists of three major subsystems: shore-side power electronics, mooring system, and turbine generator unit (TGU) device. This submission includes a technical report on control system development, supporting simulations and supervisory control and data acquisition (SCADA) system requirements. Also included is the final design of the control and SCADA system, with supporting simulations and risk mitigation control strategies to address major system technical risks.
Next Generation RivGen Power System: Risk Register
공공데이터포털
Risk Register for the RivGen power system, optimized for performance, durability and survivability, in Microsoft Excel format.
Coordinated Control of Tidal Cross-flow Turbines
공공데이터포털
Initial laboratory experiments with coordinated phase control of cross-flow turbines in a dense array.
Coordinated Control of Tidal Cross-flow Turbines
공공데이터포털
Initial laboratory experiments with coordinated phase control of cross-flow turbines in a dense array.