Utah FORGE: Updated Phase 2C Well Location Coordinates
공공데이터포털
Utah FORGE has been established to develop, test, and improve the technologies and techniques required to develop EGS-type geothermal resources. Drilling of the first of two deep deviated wells, 16A(78)-32, will begin in the second half of 2020. This well will serve as the injection well for the injection-production well pair that will form the heart of the laboratory. This submission contains an archive of well location data within the Roosevelt Hot Springs geothermal area. An Excel spreadsheet is included containing updated GPS data for Utah FORGE wells drilled during Phase 2C (56-32, 68-32, 78-32). This data was collected over time by the Utah Geological Survey and contains all coordinates collected and the final averaged XY coordinates in both Longitude and Latitude and UTM Zone 12, NAD83. Elevation is also included. GIS shapefiles with well points are provided in the archive.
Utah FORGE: Updated Phase 2C Well Location Coordinates
공공데이터포털
Utah FORGE has been established to develop, test, and improve the technologies and techniques required to develop EGS-type geothermal resources. Drilling of the first of two deep deviated wells, 16A(78)-32, will begin in the second half of 2020. This well will serve as the injection well for the injection-production well pair that will form the heart of the laboratory. This submission contains an archive of well location data within the Roosevelt Hot Springs geothermal area. An Excel spreadsheet is included containing updated GPS data for Utah FORGE wells drilled during Phase 2C (56-32, 68-32, 78-32). This data was collected over time by the Utah Geological Survey and contains all coordinates collected and the final averaged XY coordinates in both Longitude and Latitude and UTM Zone 12, NAD83. Elevation is also included. GIS shapefiles with well points are provided in the archive.
Utah FORGE: GIS Well Temperature Data
공공데이터포털
This is a GIS point feature shapefile representing wells, and their temperatures, that are located in the general Utah FORGE area near Milford, Utah. There are also fields that represent interpolated temperature values at depths of 200 m, 1000 m, 2000 m, 3000 m, and 4000 m. in degrees Fahrenheit. The temperature values at specific depths as mentioned above were derived as follows. In cases where the well reached a given depth (200 m and 1, 2, 3, or 4 km), the temperature is the measured temperature. For the shallower wells (and at deeper depths in the wells reaching one or more of the target depths), temperatures were extrapolated from the temperature-depth profiles that appeared to have stable (re-equilibrated after drilling) and linear profiles within the conductive regime (i.e. below the water table or other convective influences such as shallow hydrothermal outflow from the Roosevelt Hydrothermal System). Measured temperatures/gradients from deeper wells (when available and reasonably close to a given well) were used to help constrain the extrapolation to greater depths. Most of the field names in the attribute table are intuitive, however HF = heat flow, intercept = the temperature at the surface (x-axis of the temperature-depth plots) based on the linear segment of the plot that was used to extrapolate the temperature profiles to greater depths, and depth_m is the total well depth. This information is also present in the shapefile metadata.
Utah FORGE: GIS Well Temperature Data
공공데이터포털
This is a GIS point feature shapefile representing wells, and their temperatures, that are located in the general Utah FORGE area near Milford, Utah. There are also fields that represent interpolated temperature values at depths of 200 m, 1000 m, 2000 m, 3000 m, and 4000 m. in degrees Fahrenheit. The temperature values at specific depths as mentioned above were derived as follows. In cases where the well reached a given depth (200 m and 1, 2, 3, or 4 km), the temperature is the measured temperature. For the shallower wells (and at deeper depths in the wells reaching one or more of the target depths), temperatures were extrapolated from the temperature-depth profiles that appeared to have stable (re-equilibrated after drilling) and linear profiles within the conductive regime (i.e. below the water table or other convective influences such as shallow hydrothermal outflow from the Roosevelt Hydrothermal System). Measured temperatures/gradients from deeper wells (when available and reasonably close to a given well) were used to help constrain the extrapolation to greater depths. Most of the field names in the attribute table are intuitive, however HF = heat flow, intercept = the temperature at the surface (x-axis of the temperature-depth plots) based on the linear segment of the plot that was used to extrapolate the temperature profiles to greater depths, and depth_m is the total well depth. This information is also present in the shapefile metadata.
Utah FORGE: FSB4, FSB5, & FSB6 Shallow Seismic Well Locations
공공데이터포털
This is a PDF file generated by Woolsey Land Surveying, P.C containing the surveyed locations, as located, in Latitude and Longitude degrees, of the Utah FORGE FSB4, FSB5, & FSB6 shallow seismic well locations.